Data entity
QMSTestInstrumentCalibrationGroupEntity
Holds calibration groups for test instruments. Each group has a calibration method, a calibration period and frequency, and usage limits such as maximum usage before calibration and lifetime maximum. It also has settings for the usage count trigger, the usage increment and how usage is updated.
- Entity name
QMSTestInstrumentCalibrationGroupEntity- Public entity name
TestInstrumentCalibrationGroup- OData collection
TestInstrumentCalibrationGroups- Category
Reference- Module
Inventory and warehouse management- Read-only
No- Data management enabled
Yes- Configuration key
InventQualityManagement- Keys
GroupId- Staging table
QMSTestInstrumentCalibrationGroupStaging
Use it in Power BI and Power Platform
- OData URL
https://<environment>/data/TestInstrumentCalibrationGroups- Dataverse virtual table
mserp_qmstestinstrumentcalibrationgroupentity. Listed in the virtual-table catalogue. An administrator must make the virtual table visible before you can use it.- Data management
- Enabled: you can use it in import and export projects.
Data sources
QMSInventCalibrationGroup· root
Fields (10)
| Field and description | Type / EDT / enum | Mandatory | OData / Dataverse | References | Lineage root |
|---|---|---|---|---|---|
CalibrationMethodHow calibration is triggered: none, manual, usage or periodic. | Enum
| Yes | Yes | QMSInventCalibrationGroup.CalibrationMethod | |
CalibrationPeriodTime unit for periodic calibration: none, day, month or year. | Enum
| No | Yes | QMSInventCalibrationGroup.CalibrationPeriod | |
GroupDescriptionShort text describing the calibration group. | String (30)QMSDescription | No | Yes | QMSInventCalibrationGroup.Description | |
GroupIdUnique name of the calibration group. | StringQMSCalibrationGroupId | Yes | Yes | QMSInventCalibrationGroup.GroupId | |
MaximumUsageBeforeCalibrationMaximum usage allowed before the next calibration. | IntegerQMSMaxUsage | No | Yes | QMSInventCalibrationGroup.MaxUsage | |
MaximumLifetimeUsageMaximum total usage of the instrument over its life. | IntegerQMSMaxUsageLifetime | No | Yes | QMSInventCalibrationGroup.MaxUsageLifetime | |
CalibrationPeriodFrequencyNumber of calibration periods between scheduled calibrations. | IntegerQMSCalibrationPeriodFrequency | No | Yes | QMSInventCalibrationGroup.PeriodFrequency | |
UsageCountCalibrationTriggerUsage count at which a calibration is triggered. | IntegerQMSCalibrationUsageCountTrigger | No | Yes | QMSInventCalibrationGroup.UsageCountTrigger | |
UsageIncrementAmount added to the usage count when the fixed increment update method is used. | IntegerQMSUsageIncrement | No | Yes | QMSInventCalibrationGroup.UsageIncrement | |
UsageUpdateMethodHow usage is counted: none, fixed increment or test quantity. | Enum
| No | Yes | QMSInventCalibrationGroup.UsageUpdateMethod |
Need help with QMSTestInstrumentCalibrationGroupEntity in Power BI, Power Automate or a migration? Talk to Dr Dynamics.