Data entity

QMSTestInstrumentCalibrationGroupEntity

Holds calibration groups for test instruments. Each group has a calibration method, a calibration period and frequency, and usage limits such as maximum usage before calibration and lifetime maximum. It also has settings for the usage count trigger, the usage increment and how usage is updated.

Entity name
QMSTestInstrumentCalibrationGroupEntity
Public entity name
TestInstrumentCalibrationGroup
OData collection
TestInstrumentCalibrationGroups
Category
Reference
Module
Inventory and warehouse management
Read-only
No
Data management enabled
Yes
Configuration key
InventQualityManagement
Keys
GroupId
Staging table
QMSTestInstrumentCalibrationGroupStaging

Use it in Power BI and Power Platform

OData URL
https://<environment>/data/TestInstrumentCalibrationGroups
Dataverse virtual table
mserp_qmstestinstrumentcalibrationgroupentity. Listed in the virtual-table catalogue. An administrator must make the virtual table visible before you can use it.
Data management
Enabled: you can use it in import and export projects.

Data sources

  • QMSInventCalibrationGroup · root

Fields (10)

Field and descriptionType / EDT / enumMandatoryOData / DataverseReferencesLineage root
CalibrationMethodHow calibration is triggered: none, manual, usage or periodic.Enum
QMSCalibrationMethod
  • None 0
  • Manual 1
  • Usage 2
  • Periodic 3
YesYesQMSInventCalibrationGroup.CalibrationMethod
CalibrationPeriodTime unit for periodic calibration: none, day, month or year.Enum
QMSCalibrationPeriod
  • None 0
  • Day 1
  • Month 2
  • Year 3
NoYesQMSInventCalibrationGroup.CalibrationPeriod
GroupDescriptionShort text describing the calibration group.String (30)
QMSDescription
NoYesQMSInventCalibrationGroup.Description
GroupIdUnique name of the calibration group.String
QMSCalibrationGroupId
YesYesQMSInventCalibrationGroup.GroupId
MaximumUsageBeforeCalibrationMaximum usage allowed before the next calibration.Integer
QMSMaxUsage
NoYesQMSInventCalibrationGroup.MaxUsage
MaximumLifetimeUsageMaximum total usage of the instrument over its life.Integer
QMSMaxUsageLifetime
NoYesQMSInventCalibrationGroup.MaxUsageLifetime
CalibrationPeriodFrequencyNumber of calibration periods between scheduled calibrations.Integer
QMSCalibrationPeriodFrequency
NoYesQMSInventCalibrationGroup.PeriodFrequency
UsageCountCalibrationTriggerUsage count at which a calibration is triggered.Integer
QMSCalibrationUsageCountTrigger
NoYesQMSInventCalibrationGroup.UsageCountTrigger
UsageIncrementAmount added to the usage count when the fixed increment update method is used.Integer
QMSUsageIncrement
NoYesQMSInventCalibrationGroup.UsageIncrement
UsageUpdateMethodHow usage is counted: none, fixed increment or test quantity.Enum
QMSCalibrationUsageUpdateMethod
  • None 0
  • FixedIncrement 1
  • TestQuantity 2
NoYesQMSInventCalibrationGroup.UsageUpdateMethod

Need help with QMSTestInstrumentCalibrationGroupEntity in Power BI, Power Automate or a migration? Talk to Dr Dynamics.