Table
InventGateEntryHeaderFooterTmp_IN Temporary
Show gate entry
Purpose not clear from the metadata.
- Table name
InventGateEntryHeaderFooterTmp_IN- Module
Cross-module and platform- Table group
Miscellaneous- Table type
TempDB- Data per company
Yes- Configuration key
None- Primary index
None- Replacement key
None- Key fields
None- Model
Foundation
Fields (28)
| Field and description | Type / EDT / enum | Mandatory | References | In public entities |
|---|---|---|---|---|
ApproverEmployeeNameNo description | String (160)HcmWorkerName | No | None | |
ArrivalDateAndTimeNo description | UtcDateTimeInventSiteGateEntryArrivalDateAndTime_IN | No | None | |
ChallanDateNo description | DateChallanDate_IN | No | None | |
ChallanNumberNo description | String (20)ChallanNumber_IN | No | None | |
CompanyAddressNo description | String (250)Addressing | No | None | |
CompanyNameNo description | String (60)CompanyName | No | None | |
DescriptionNo description | String (60)Description | No | None | |
DriverMobilePhoneNo description | String (20)DriverMobilePhone_IN | No | None | |
EntryIdNo description | String (20)InventSiteGateEntryId_IN | No | None | |
ExitDateAndTimeNo description | UtcDateTimeInventSiteGateEntryExitDateAndTime_IN | No | None | |
GateIdNo description | String (20)InventSiteGateId_IN | Yes | None | |
InventLocationIdNo description | StringInventLocationId | No | None | |
OriginCityNo description | String (60)OriginCity_IN | No | None | |
PartitionA system field for the data partition. In most environments every record has the same value. System field. | Int64Partition | No | None | |
RecIdA unique number that the system gives to every record. Other tables often use it to point to this record. System field. | Int64RecId | No | None | |
RecVersionA system number that changes each time the record is updated. It is used to detect conflicting updates. System field. | IntegerRecVersion | No | None | |
ReferenceDocumentTypeNo description | String (60)Description | No | None | |
ReferencePartyIdNo description | String (20)InventSiteGateRefPartyId_IN | No | None | |
RetrunableGatePassNumberNo description | String (20)RetrunableGatePassNumber_IN | No | None | |
SiteIdNo description | StringInventSiteId | Yes | None | |
StatusNo description | String (60)Description | No | None | |
TableIdA system number that identifies the table. System field. | IntegerTableId | No | None | |
TransportationCompanyNameNo description | String (60)TransportationCompanyName_IN | No | None | |
TransportationDriverNameNo description | String (60)TransportationDriverName_IN | No | None | |
TransportationReceiptDateNo description | DateTransportationReceiptDate_IN | No | None | |
TransportationReceiptNumberNo description | String (20)TransportationReceiptNumber_IN | No | None | |
TypeNo description | String (60)Description | No | None | |
VehicleNumberNo description | String (20)VehicleNumber_IN | No | None |
Get this data out
No public entity reads from InventGateEntryHeaderFooterTmp_IN. Its data is only reachable through the application, a custom entity or a database export.
Need help with InventGateEntryHeaderFooterTmp_IN in a report, an integration or a migration? Talk to Dr Dynamics.