Table

InventTestCertOfAnalysisLine

Certificate of analysis lines

Holds the test lines of a certificate of analysis. Each line is identified by the certificate, a sequence number and a test. It records the limits, tolerances, standard value, unit and pass or fail result for that test.

Table name
InventTestCertOfAnalysisLine
Module
Inventory
Table group
WorksheetLine
Table type
Regular
Data per company
Yes
Configuration key
InventQualityManagement
Primary index
CertOfAnalysisLineIdx
Replacement key
CertOfAnalysisLineIdx
Key fields
InventCertificateOfAnalysisId, TestSequence, TestId
Model
Foundation

Fields (20)

Field and descriptionType / EDT / enumMandatoryReferencesIn public entities
InventCertificateOfAnalysisIdThe certificate of analysis the line belongs to.String (20)
InventCertificateOfAnalysisId
YesInventTestCertOfAnalysisTable.InventCertificateOfAnalysisIdNone
TestSequenceSequence number that orders the test within the certificate.Integer
InventTestSequence
YesNone
TestIdThe test the line refers to.String (20)
InventTestId
YesInventTestTable.TestIdNone
CreatedByThe user who created the record. System field.String (20)
CreatedBy
NoNone
CreatedDateTimeThe date and time when the record was created. System field.UtcDateTime
CreatedDateTime
NoNone
DataAreaIdThe company (legal entity) that the record belongs to. System field.String (4)
DataAreaId
NoNone
LowerLimitMinimum allowed value for the test.Real
InventTestLowerLimit
NoNone
LowerToleranceLower tolerance, as a percentage.Real
InventTestLowerTolerance
NoNone
ModifiedByThe user who last changed the record. System field.String (20)
ModifiedBy
NoNone
ModifiedDateTimeThe date and time when the record was last changed. System field.UtcDateTime
ModifiedDateTime
NoNone
PartitionA system field for the data partition. In most environments every record has the same value. System field.Int64
Partition
NoNone
RecIdA unique number that the system gives to every record. Other tables often use it to point to this record. System field.Int64
RecId
NoNone
RecVersionA system number that changes each time the record is updated. It is used to detect conflicting updates. System field.Integer
RecVersion
NoNone
StandardValueStandard (target) value for the test.Real
InventTestStandardValue
NoNone
TableIdA system number that identifies the table. System field.Integer
TableId
NoNone
TestResultOverall result of the test, pass or fail.Enum
InventTestOutcomeStatus (enum)
NoNone
TestUnitIdUnit of measure used for the test values.String
UnitOfMeasureSymbol
NoUnitOfMeasure.SymbolNone
UpperLimitMaximum allowed value for the test.Real
InventTestUpperLimit
NoNone
UpperToleranceUpper tolerance, as a percentage.Real
InventTestUpperTolerance
NoNone
VariableOutcomeIdStandardThe default outcome for the test, taken from the test variable outcomes.String (20)
InventTestVariableOutcomeIdStandard
NoNone

Indexes (1)

Relations (4)

Each relation joins InventTestCertOfAnalysisLine to another table on the fields shown.

  • InventTestCertOfAnalysisTable → InventTestCertOfAnalysisTable

    Join on InventCertificateOfAnalysisId = InventTestCertOfAnalysisTable.InventCertificateOfAnalysisId

    Many InventTestCertOfAnalysisLine records → exactly one InventTestCertOfAnalysisTable record

  • InventTestTable → InventTestTable

    Join on TestId = InventTestTable.TestId

    Many InventTestCertOfAnalysisLine records → exactly one InventTestTable record

  • InventTestVariableOutcome → InventTestVariableOutcome

    Join on VariableOutcomeIdStandard = InventTestVariableOutcome.VariableOutcomeId

    Many InventTestCertOfAnalysisLine records → zero or one InventTestVariableOutcome record

  • UnitOfMeasure → UnitOfMeasure

    Join on TestUnitId = UnitOfMeasure.Symbol

    Many InventTestCertOfAnalysisLine records → zero or one UnitOfMeasure record

Get this data out

No public entity reads from InventTestCertOfAnalysisLine. Its data is only reachable through the application, a custom entity or a database export.

Need help with InventTestCertOfAnalysisLine in a report, an integration or a migration? Talk to Dr Dynamics.

Email sales@drdynamics.co.uk