Table

QMSInventCalibrationGroup

Calibration groups

Lists calibration groups for test instruments. Each group sets how calibration is triggered, by method, period or usage, and sets usage limits.

Table name
QMSInventCalibrationGroup
Module
Cross-module and platform
Table group
Group
Table type
Regular
Data per company
Yes
Configuration key
InventQualityManagement
Primary index
InventCalibrationGroupIdx
Replacement key
InventCalibrationGroupIdx
Key fields
GroupId
Model
AdvancedQualityManagement

Fields (16)

Field and descriptionType / EDT / enumMandatoryReferencesIn public entities
GroupIdUnique name of the calibration group.String
QMSCalibrationGroupId
YesQMSTestInstrumentCalibrationGroupEntity
CalibrationMethodHow calibration is triggered: none, manual, usage or periodic.Enum
QMSCalibrationMethod (enum)
YesQMSTestInstrumentCalibrationGroupEntity
CalibrationPeriodTime unit for periodic calibration: none, day, month or year.Enum
QMSCalibrationPeriod (enum)
NoQMSTestInstrumentCalibrationGroupEntity
DataAreaIdThe company (legal entity) that the record belongs to. System field.String (4)
DataAreaId
NoNone
DescriptionShort text describing the calibration group.String (30)
QMSDescription
NoQMSTestInstrumentCalibrationGroupEntity
MaxUsageMaximum usage allowed before the next calibration.Integer
QMSMaxUsage
NoQMSTestInstrumentCalibrationGroupEntity
MaxUsageLifetimeMaximum total usage of the instrument over its life.Integer
QMSMaxUsageLifetime
NoQMSTestInstrumentCalibrationGroupEntity
PartitionA system field for the data partition. In most environments every record has the same value. System field.Int64
Partition
NoNone
PeriodFrequencyNumber of calibration periods between scheduled calibrations.Integer
QMSCalibrationPeriodFrequency
NoQMSTestInstrumentCalibrationGroupEntity
RecIdA unique number that the system gives to every record. Other tables often use it to point to this record. System field.Int64
RecId
NoNone
RecVersionA system number that changes each time the record is updated. It is used to detect conflicting updates. System field.Integer
RecVersion
NoNone
SysRowVersionA system row version number that is used for change tracking. System field.Int64
SysRowVersion
NoNone
TableIdA system number that identifies the table. System field.Integer
TableId
NoNone
UsageCountTriggerUsage count at which a calibration is triggered.Integer
QMSCalibrationUsageCountTrigger
NoQMSTestInstrumentCalibrationGroupEntity
UsageIncrementAmount added to the usage count when the fixed increment update method is used.Integer
QMSUsageIncrement
NoQMSTestInstrumentCalibrationGroupEntity
UsageUpdateMethodHow usage is counted: none, fixed increment or test quantity.Enum
QMSCalibrationUsageUpdateMethod (enum)
NoQMSTestInstrumentCalibrationGroupEntity

Indexes (1)

  • InventCalibrationGroupIdxPrimary indexReplacement key

    GroupId

    Unique, alternate key.

Get this data out

Tables are not exposed directly. These public entities read from QMSInventCalibrationGroup; use one of them in Power BI, Power Platform or a data management project.

Need help with QMSInventCalibrationGroup in a report, an integration or a migration? Talk to Dr Dynamics.

Email sales@drdynamics.co.uk