Table
QMSInventCalibrationGroup
Calibration groups
Lists calibration groups for test instruments. Each group sets how calibration is triggered, by method, period or usage, and sets usage limits.
- Table name
QMSInventCalibrationGroup- Module
Cross-module and platform- Table group
Group- Table type
Regular- Data per company
Yes- Configuration key
InventQualityManagement- Primary index
InventCalibrationGroupIdx- Replacement key
InventCalibrationGroupIdx- Key fields
GroupId- Model
AdvancedQualityManagement
Fields (16)
| Field and description | Type / EDT / enum | Mandatory | References | In public entities |
|---|---|---|---|---|
GroupIdUnique name of the calibration group. | StringQMSCalibrationGroupId | Yes | QMSTestInstrumentCalibrationGroupEntity | |
CalibrationMethodHow calibration is triggered: none, manual, usage or periodic. | EnumQMSCalibrationMethod (enum) | Yes | QMSTestInstrumentCalibrationGroupEntity | |
CalibrationPeriodTime unit for periodic calibration: none, day, month or year. | EnumQMSCalibrationPeriod (enum) | No | QMSTestInstrumentCalibrationGroupEntity | |
DataAreaIdThe company (legal entity) that the record belongs to. System field. | String (4)DataAreaId | No | None | |
DescriptionShort text describing the calibration group. | String (30)QMSDescription | No | QMSTestInstrumentCalibrationGroupEntity | |
MaxUsageMaximum usage allowed before the next calibration. | IntegerQMSMaxUsage | No | QMSTestInstrumentCalibrationGroupEntity | |
MaxUsageLifetimeMaximum total usage of the instrument over its life. | IntegerQMSMaxUsageLifetime | No | QMSTestInstrumentCalibrationGroupEntity | |
PartitionA system field for the data partition. In most environments every record has the same value. System field. | Int64Partition | No | None | |
PeriodFrequencyNumber of calibration periods between scheduled calibrations. | IntegerQMSCalibrationPeriodFrequency | No | QMSTestInstrumentCalibrationGroupEntity | |
RecIdA unique number that the system gives to every record. Other tables often use it to point to this record. System field. | Int64RecId | No | None | |
RecVersionA system number that changes each time the record is updated. It is used to detect conflicting updates. System field. | IntegerRecVersion | No | None | |
SysRowVersionA system row version number that is used for change tracking. System field. | Int64SysRowVersion | No | None | |
TableIdA system number that identifies the table. System field. | IntegerTableId | No | None | |
UsageCountTriggerUsage count at which a calibration is triggered. | IntegerQMSCalibrationUsageCountTrigger | No | QMSTestInstrumentCalibrationGroupEntity | |
UsageIncrementAmount added to the usage count when the fixed increment update method is used. | IntegerQMSUsageIncrement | No | QMSTestInstrumentCalibrationGroupEntity | |
UsageUpdateMethodHow usage is counted: none, fixed increment or test quantity. | EnumQMSCalibrationUsageUpdateMethod (enum) | No | QMSTestInstrumentCalibrationGroupEntity |
Indexes (1)
InventCalibrationGroupIdxPrimary indexReplacement keyUnique, alternate key.
Get this data out
Tables are not exposed directly. These public entities read from QMSInventCalibrationGroup; use one of them in Power BI, Power Platform or a data management project.
QMSTestInstrumentCalibrationGroupEntity· 10 fields from this table
Need help with QMSInventCalibrationGroup in a report, an integration or a migration? Talk to Dr Dynamics.